R3-50 Research Anemometer

The R3-50 3-axis anemometer has been designed for scientific research, particularly suitable for determining fluxes using the eddy covariance technique.

This precision ultrasonic anemometer will monitor wind speeds up to 45m/s, with a fast data output rate of 50Hz (100Hz model available, click here to view). U, V, W and SOS (sonic temperature) outputs are available, and data can be logged using the supplied Gill WindCom software.

The R3-50 anemometer has a robust, lightweight aluminium/carbon fibre construction and can be supplied with accessories that include cables, sensor input units (analogue inputs) and power supplies.

For applications where a faster 100Hz data output rate is required the R3-100 is recommended.



Key Benefits

  • 3-axis research anemometer
  • U, V, W vector outputs
  • 50Hz output rate
  • Sonic temperature output
  • 0-45 m/s wind speed
  • Aluminium/carbon fibre construction
  • 0-359° wind direction
  • Custom calibration provided as standard

Wind Speed Specifications
Range
0-45m/s
Accuracy
<1.0% RMS
Resolution
0.01m/s
Wind Direction Specifications
Range
0-359º
Accuracy
<±1.0º RMS
Resolution
Speed of Sound
Range
300 - 370m/s
Resolution
0.01 m/s
Accuracy
< ±0.5% @ 20ºC
Measurement
Ultrasonic Output Rate
50Hz
Output Formats
UVW, Speed of Sound
Digital Output
Communication
RS422 full duplex, 8 data bits, 1 stop bit, no parity
Baud Rates
2400 - 115200
Output Rate
Selectable 0.4 to 50s
PRT Input
Input Resolution
0.01°C
Input Accuracy
<0.01°C (0°C to +50°C)
<0.15°C (-40°C to +60°C)
Analogue Outputs (Requires PCIA unit)
Quantity
7 (U,V,W, SOS, PRT plus 2 analogue inputs)
Scale
±10, ±20, ±30, ±60 m/s
Update Rate
0.4 to 50s
Range and Resolution
±2.5V, 14 bits
Accuracy
<0.1% of FSR
Analogue Inputs (Requires SIU)
Quantity
6 differential inputs
Sampling Rate
50s
Range and Resolution
±5V, 14 bits
Accuracy
<0.1% of FSR
Power Requirement
Anemometer
9-30V DC (<150mA @ 24V DC or 300mA @ 12V DC)
Mechanical
Material
Aluminium / Carbon Fibre
Weight
1.0 Kg
Size
750mm x 240mm
Environmental
Protection Class
IP65
Operating Temperature
-40ºC to +60ºC
Precipitation
300mm/hr
EMC
Emissions BS EN 50081-1 : 1992