Rated voltage: 115 VAC or 230 VAC +15% -20% on request 65à·250 VAC / 90à·250 VDC on request 19à·60 VDC on request
Consumption: 2 VA max
Maximum measurable voltage: 600 (750) VAC max L-L
Input impedance: ›1.3 MOhm
Burden: max 0.15 VA per phase
Frequency: 45 - 65 Hz
Rated current (Ib): 1 / 5 ARMS programmable
Min / max measurable current: 20 mA / 7 ARMS
Maximum overload: 10 ARMS continuous - 100 ARMS for 1 sec.
Input impedance: 0,02 Ohm approximately
Burden: max 0,5 VA per phase
Insulation voltage: 150 VAC max between phases
Rogowski input: 200à·49995 A on request
Voltage: ±0.2% reading ±0.1% full scale
Current: ±0.2% reading ±0.1% full scale
Active power: ±1% reading ±0.2% full scale (PF=1)
Power factor: ±1% reading (0.5 inductive - 0.8 capacitive)
Active energy: ±1% reading (0.5 inductive - 0.8 capacitive)
Frequency: ±0.05% reading ±1 digit from 45 to 65 Hz
Display: high brightness 14 mm LED display three lines, four digits (eight for energies)
Keypad: 2 push-buttons
Type: RS232 or RS485 on request, optoisolated
Baud rate: programmable from 300 to 57600 bps 78 kbps fixed, in case of LONBUS up to 12 Mbps, in case of PROFIBUS 10/100 Mbps, in case of ETHERNET on LAN side
Type: 2 optoisolated (50V-100mACA-CC)
Operating temperature: from -15 °C to +60 °C
Storage temperature: from -30 °C to +75 °C
Relative humidity: 80% max. without condensation
Material: plastic enclosure
Protection degree: IP54 (front panel); IP20 (terminals)
Terminals: conductors 2.5 mm2
Size / weight: 96x96x60 mm or 96x96x100 mm 500 gr max, depending on the configuration
Safety: 73/23/EEC and 93/68/EEC directives, EN61010.1 safety standard
EMC: 89/366/EEC directive and following modifications 93/31/EEC and 93/68/EEC, EN50081-2, EN50082-2, EN61326/A1