TRACK POWER USAGE, ENERGY COSTS WITH OUR WORKHORSE POWER ANALYZER
Get complete power usage and energy cost analysis in a compact, rugged package. The PowerSight PS3550 measures voltage, current, KW, KVA, KVAR, true power factor, displacement power factor, KWh, Hz, elapsed and estimated cost, duty cycle.
Long term logging for up to months at a time.
Manual waveform capture ability. Real time meter display of present values.
Bluetooth wireless and CAT IV 600V safety rating for highest safety. SD card for speed and data redundancy. The best all-around workhorse for power consumption monitoring and harmonic analysis.
Its rubberized contoured case and rugged construction make the PS3550 ideal for field work. Clearly labeled buttons display present values on a back-lit LCD display for quickly making spot measurements at panels and equipment. Our patented SureStart feature automatically checks for wrong connections before you begin monitoring to ensure a successful power study every time.
Use it on AC single phase or three phase circuits and loads. Data is saved to internal memory that can be downloaded to a PC via Bluetooth. Alternatively, the PS3550 includes a removable SD memory card slot (to 32GB capacity) that allows you to backup power survey data and transfer the data to a PC via an SD card. PowerSight Manager software with ReportWriter are included.
Going green? Need to control energy costs and implement energy savings measures? The PS3550 is ideal for establishing base-line data, and verifying the savings after changes have been made.
The new safety regulations demand safer tools. The PowerSight PS3550 has a 600V CAT IV safety rating (1000V CAT III) - the smart choice for working on systems to 1000V.
PowerSight analyzers with Bluetooth wireless communications are the safest way to test. After installing the PowerSight analyzer and its probes, workers can get away from high voltages and Arc Flash dangers and test remotely. When at a safe distance, cumbersome PPE suits, hoods, gloves etc. can be removed. Thus workers can more comfortably control the PowerSight, view connections, phasors, and real-time values, start/stop monitoring and download data in complete safety (up to 25 feet away) via a laptop or tablet PC.
Measures, logs, and reports:
Category | Notes |
---|---|
Size: | 3.89" (9.86 cm) W x 7.72" (19.61 cm) L x 1.58" (4.01 cm) Deep at bottom end; 2.14" (5.44 cm) Deep at top end |
Weight | 1.1 lbs (0.5 kg) |
Operating Range | 32 - 122 degrees F (0 - 50 degrees C) Relative humidity to 70% (non-condensing) |
Power Requirement | 12V DC @ 500 mA. |
Battery Life | 8-10 hours after 4 hour charge |
Battery Type | Li-ion |
Sampling Rate | 8 microseconds for Voltage and Current |
Safety | 1000V CAT III, 600V CAT IV |
SD Card Slot | Accepts SD Cards to 32GB |
Logging Period (Resolution) | 1 Second - 99 Minutes (set by user) |
Logging Duration (Length of session) | up to 2 years according to memory allocation |
Internal Data Retention | 8 years |
Other Features | Crest Factor, K Factor, Peak Demand Period, Peak Demand of Peak, Demand Period. Duty Cycle, On/Off Cycle %, Avg. On Time, Avg Off Time |
Category | Notes |
---|---|
Display Range | 1-6000 KV (using input ratios) |
Meter Resolution | 0.1V (to 400 V), 1V (to 4 KV) |
Accuracy | 0.5% of reading ±0.3 Vrms |
Category | Notes |
---|---|
Display Range | 1 mA - 6 Megamps (using input ratios) |
Meter Display Resolution | 0.1A |
Accuracy | ±0.5 % of reading plus accuracy of probes |
Phasor Diagram | Via PC |
Imbalance | Via PC |
Category | Notes |
---|---|
Range | DC: 45-66 Hz, 360-440 Hz fundamental |
Meter Display Resolution | 0.1 Hz (to 66.0 Hz) |
Accuracy | ±0.5% |