DT80G




Key Features
  • Universal – compatible with majority of the commercially available sensors
  • Programmable – customised software deployment for changing and challenging requirements
  • High input Impedance – ensure accurate sensor readings
  • Expandable – expandable to 300 analogue inputs with expansion module
  • Programmable analogue output – for connection to SCADA or control application
  • Additional support for vibrating-wires
  • Carlson, electro level & LVDT support
  • Capable to test sensor integrity through audible frequency
Data Storage and Communications Ports RS232

Geotechnical Logger

Advanced design and technology plus 25 years of geotechnical expertise have produced the dataTaker DT80G GeoLogger – A versatile, powerful – yet low power & cost effective data logger.

It support vibrating wire and other geotechnical sensors such as Slope Indicator, RST Instruments, Geokon, Soil Instruments, Roctest, AGI – Applied Geomechanics Inc. DT80G is also capable to test sensor integrity through audible frequency

With temperature compensation (thermistor), 5 analog channels are capable to read up to 5 vibrating wire sensors. If temperature compensation is not required this logger can read up to 15 vibrating wire sensors.

Further expansion up to 100 sensors (with temperature compensation) or 300 sensors(without temperature compensation) is possible.

Applications
  • Land slide prevention
  • Structural strength diagnosis
  • Dam-wall monitoring
  • Tunnel monitoring
  • Concrete curing
  • Mining exploration
  • Pipelines monitoring
  • Earthquake early detection

Superior Data Storage and Communications

With the standard unit able to store up to 10 million data points (expandable) you can log as much or as little as you need. Overwrite or stop logging once allocated memory is full,archive data on alarm event, copy to USB memory or transfer via FTP/ Email, the choice is yours.

Communications features include RS232, USB and Ethernet, connect to the DT80G locally, remotely through a modem or over the Internet. The web interface allows users to configure the DT80G, access logged data and see current measurements as mimics or in a list using a web browser.

FTP/ Email provides data to your office over the internet or wireless network, without the need for polling or specific host software.


Download Brochure

Max Sampling rate (Hz) 40
Analog Inputs 15 (2-wire common reference)
10 (2-wire isolated)
5 (3 and 4 wire isolated)
Analog Input Range Voltage: ±30m,300m,3000m,50000mVDC
Current: ±30mA
Resistance: 1MΩ
Frequency: 450kHz
Analog Voltage Accuracy ±0.15 of Reading + (Full Scale Reading * 0.01%)
Effective Resolution 18 bits
Analog Outputs 1
Analog Out Range Voltage: 10m-10000mVDC
Current: 0-24mA
Excitation Analog Channel: selectable 2µA, 250µA or 2.5mA precision current source, 4.5V voltage source or switched external supply
Switchable 12V/5 regulated power output (max 300mA)
Digital IO 8 bi-directional channels
Counter Low speed counters: 8 counters shared with digital inputs
Dedicated counters: 4 high speed or 2 phase encoder
RS232/RS422/RS485 serial sensor port 1
RS232 host port 1
USB Port 1
Ethernet Port 1
Data Storage 128MB (upgradeable to 2GB)
Vibrating Wire Supported 128MB (upgradeable to 2GB)
Protocols Supported Modbus, FTP, HTTP, XML, SMTP, NTP and SDI-12
CEM20 Expansion Module supported Yes
Power Requirements 10-30 VDC
Internal Battery 6Vdc 1.2Ah Lead Acid
Real Time Clock Accuracy ± 1 min/year (0°C to 40°C)
± 4 min/year (–40°C to 70°C)
Dimensions(mm) 180x137x65
Weight 1.5kg
Temperature Range –45°C to 70°C
Warranty 3 years

Central Market Abu Dhabi

The Central Market in Abu Dhabi is a huge construction project which is due for completion in 2011. It consists of three towers, the Residential Tower, the Commercial Tower and the Hotel Tower. The tallest will be the Residential Tower which will stand 381 metres tall with 88 floors. It is imperative that certain parameters identifying the structural integrity be monitored and logged during construction. The diaphragm walls also require monitoring during the construction period to ensure the safety of the people and equipment on-site…